Walkin Freezers & Coolers featuring the Tafco E (Eco) Series Commercial Refrigeration System

Walkin Freezers and Coolers with theTafco E Series Commercial Regrigeration System are the most energy efficient, for the capital expenditure, of the Tafco Refrigeration Systems. Customers will realize
the quickest return on investment with the purchase of this system.

Download Data Sheet

The Tafco Eco (E) Series is our most energy efficient system for your money. The Tafco Eco Series comes with a 1 year warranty on parts and 60 days on labor. The system incorporates a number of features which enhance walkin freezer and cooler performance, provide energy savings over our Tafco Value Series, and increase reliability, thus saving you money. This is done by a design that eliminates the need for a refrigerant receiver by providing built-in storage capacity in the condenser section of the condensing unit. This small change allows for the addition of new features that are not possible in the traditional refrigeration systems. It actually gives the same size condenser up to 20% more capability by providing a potential 50% increase in condenser surface. This feature increases compressor size and lower operating pressure provides an initial energy savings of up to 10%. This feature provides 30% in additional energy savings during low ambient conditions. Additionally, it also supplies sub-cooled liquid refrigerant to the expansion valve to maintain optimum valve performance.

Walkin Freezers and Coolers with E (Eco) Series refrigeration systems can offer energy savings of up to 40% over conventional walkin freezer and cooler refrigeration systems (see graph below). Tafco E Series systems require up to 20% less refrigerant to operate, while maintaining continuous peak performance. In typical systems, the receiver, its outlet valve, and piping will create bubbles in the sight-glass due to the pressure drop they create. By eliminating the receiver and its piping components, the clearing of the sight-glass occurs much faster and with less refrigerant. The E Series sight-glass signals when the ideal charge has been attained, thus saving refrigerant and its cost.

walkin freezer energy-savings

Pre-Assembled Condensing Units Consist of the Following Parts Mounted:
• Copeland semi-hermetic, hermetic, discus, or scroll compressors
• Oil pressure control, where applicable
walkin freezer unit• High and low pressure controls
• Crankcase heater
• Low profile galvanized steel housing
• Fan cycle control (dual fan condensing unit only)
• Electric defrost provisions on low temp evaporator(s)
• 115 V air defrost clock, shipped loose
• Floating head pressure control
• Copper tube, aluminum fin condenser
• Vibrasorbers (semi-hermetic models only)
• Large electrical control panel
• Compressor contactor or start kit
• Liquid line charging valve
• Liquid line filter-dryer
• Sight-glass with moisture indicator
• Suction line filter
• Liquid refrigerant sub-cooling circuit

Pre-Assembled Evaporators Consist of the Following Parts Mounted:
• Matching low profile evaporators
• Specially sized balanced port expansion valve(s)
• ECM evaporator fan motors: 115 V coolers and 220 V freezers
• ECM evaporator fan motors use 71% less electricity than shaded pole motors
walkin freezer• Freezer evaporators are electric defrost 220 V
• Cooler evaporators are air defrost 115 V
• Liquid solenoid valve(s)
• Mechanical room thermostat

Pre-Assembled System Options:
• Copper finned condenser and evaporator coils
• AST coated condenser and evaporator coils
• Adjustable defrost controls
• Suction accumulator
• Oil separator
• Electronic controls
• Remote monitoring and control

Pre-Charged Units Add the Following:
• Correct refrigerant charge in the system
• Reusable quick connect fittings mounted to the evaporator(s) and condensing unit
• Refrigeration line set: 10’, 20’, 30’, 40’, and 50’
• Evaporator voltage matches the condensing unit voltage

* All Tafco Refrigeration Systems meet or exceed the 2007 EISA standards.